Drug
Olopatadine Hydrochloride And Mometasone Furoate
Important: Reactions below are the flagged terms from this drug’s
FAERS report history (min. 3 co-reports per term) — PRR/ROR indicate
disproportionality in spontaneous reporting, not causation.
Data from FDA FAERS via openFDA. Last recalculated: 2026-09-14.
| Reaction | Co-reports (a) | PRR | ROR | Signal | |
|---|---|---|---|---|---|
| 1 | Device Delivery System Issue | 702 | 291.1 | 449.3 | signal |
| 2 | Device Occlusion | 133 | 101.8 | 109.0 | signal |
| 3 | Drug Dose Omission By Device | 519 | 71.9 | 97.0 | signal |
| 4 | Device Defective | 63 | 41.2 | 42.5 | signal |
| 5 | Wrong Technique In Device Usage Process | 144 | 33.3 | 35.8 | signal |
| 6 | Product Use In Unapproved Indication | 607 | 26.3 | 37.4 | signal |
| 7 | Product Use Issue | 426 | 24.1 | 30.4 | signal |
| 8 | Product Odour Abnormal | 21 | 21.4 | 21.6 | signal |
| 9 | Device Failure | 29 | 20.2 | 20.5 | signal |
| 10 | Device Issue | 159 | 19.2 | 20.8 | signal |
| 11 | Product Prescribing Issue | 36 | 18.7 | 19.0 | signal |
| 12 | Drug Effective For Unapproved Indication | 51 | 18.4 | 18.9 | signal |
| 13 | Epistaxis | 125 | 17.6 | 18.7 | signal |
| 14 | Device Mechanical Issue | 20 | 16.4 | 16.5 | signal |
| 15 | Product Taste Abnormal | 17 | 13.3 | 13.4 | signal |
| 16 | Incorrect Dose Administered By Device | 31 | 12.9 | 13.1 | signal |
| 17 | Product Packaging Quantity Issue | 10 | 9.7 | 9.7 | signal |
| 18 | Dry Throat | 9 | 9.4 | 9.4 | signal |
| 19 | Drug Ineffective For Unapproved Indication | 46 | 8.7 | 8.9 | signal |
| 20 | Seasonal Allergy | 9 | 6.7 | 6.8 | signal |
| 21 | Poor Quality Product Administered | 6 | 6.2 | 6.2 | signal |
| 22 | Device Breakage | 23 | 6.2 | 6.2 | signal |
| 23 | Drug Effect Less Than Expected | 8 | 6.0 | 6.0 | signal |
| 24 | Anosmia | 8 | 5.8 | 5.8 | signal |
| 25 | Throat Irritation | 19 | 4.5 | 4.5 | signal |
| 26 | Nasal Congestion | 24 | 4.3 | 4.4 | signal |
| 27 | Inability To Afford Medication | 4 | 4.3 | 4.3 | signal |
| 28 | Sneezing | 8 | 3.8 | 3.8 | signal |
| 29 | Device Malfunction | 22 | 3.5 | 3.5 | signal |
| 30 | Sleep Disorder Due To A General Medical Condition | 5 | 3.3 | 3.3 | signal |
| 31 | Wrong Technique In Product Usage Process | 62 | 3.2 | 3.3 | signal |
| 32 | Device Use Issue | 5 | 3.0 | 3.1 | signal |
| 33 | Product Availability Issue | 6 | 2.8 | 2.8 | signal |
| 34 | Device Leakage | 8 | 2.0 | 2.0 | no signal |
| 35 | Device Difficult To Use | 9 | 1.4 | 1.4 | no signal |
| 36 | Product Storage Error | 9 | 1.1 | 1.1 | no signal |
| 37 | Device Use Error | 3 | 0.9 | 0.9 | no signal |